Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Two ways to get copper rivets out of a Mamod boiler - The

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Two ways to get copper rivets out of a Mamod boiler - The
  • Supply Capacity : 10 units/month :Two ways to get copper rivets out of a Mamod boiler - The
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Two ways to get copper rivets out of a Mamod boiler - The

    Apr 20, 2020 · Method one, is to take out the water plug, the whistle and the safety valve and use a Hoover over either the whistle or safety valve bush with the tank inverted then shake the rivets around the tank until they are sucked out. Method two, as the copper rivets are blind there should be a piece of the steel mandrel left inside the rivet.Get Price

  • MAMOD (and WILESCO) BOILER FILLER & SUCKER TE1A and ALL

    Established 2004 BOILER WATER FILLER & SUCKER FOR MAMOD AND WILESCO ENGINES "You are fed up with spending too long dribbling water into your boiler and then spilling it everywhere." This is so simple. Use this bad boy to suck up a gulp of hot water and just squirt it into the boiler. It takes seconds! And then suck out excess water after the steam-up.Get Price

  • Little Steamers and Their Boilers

    I found the performance of this boiler to be excellent. Indoors and out, generation exceeded the consumption of a pair of 9/16" X 5/8" cylinders. John Turner Models then decided to adopt the porky, but instead of my tailored spikes, simply used a host of 3/32" X 3/4" copper rivets inserted more than half way, in about five longitudinal runs.Get Price

  • Copper boiler plate flanging, or not? | Model Engineer

    Sep 07, 2020 · Older copper boilers do develop leaks around the fire door ring / section and around the foundation ring. Agreed model boilers less likely to develop cracks in the backhead / inner firebox due to the malleability of the copper (although copper does work harden even in a …Get Price

  • Three Cylinder Mamod - Roly Williams

    This I made with a bit of brass tube from the junk box. Not genuine Mamod but not too obvious. I may be able to re-do this bit later if I can get hold of some replacement Mamod tee pieces. The exhaust for the third cylinder, the one furthest from the boiler, had to be made up from a new length of pipe. At least it was genuine Mamod 1/8" copper Get Price

  • Mamod Models - Page 1 - Scale Models - PistonHeads UK

    Apr 16, 2017 · I jave taken the wheels, flywheel and piston mechanism and drilled the rivets out. Was hoping to get the whistle off and remove the boiler from the firebox, but disaster!Get Price

  • TE1A boiler rivet question - The Unofficial Mamod & Other

    Apr 16, 2011 · If you mean solid rivets, you need tools called rivet punches, also called rivet head sets, in probably three types. You also need a drawing-up tool for the size of shank on your rivets. If you are working inside a boiler, you also need a dollie, which holds the head set inside a close space. I don't. know where to get them in your area.Get Price

  • Brass screws insted of rivets? - The Unofficial Mamod

    Mamod copper boiler rivets. Early Mamod Traction engine Steam pipes Circa 1965. £3: Mamod Traction engine Steam pipes. Mamod TE1a chimney Just needs a repaint. Mamod TE chimney. Mamod TE1a chimney. Original brass coupling to attach Traction engine to driving stick Complete with brass locking nut. £4 each.Get Price

  • UNIT 3 RIVETED JOINTS Riveted Joints - IGNOU

    However, the rivets in copper add to resistance against corrosion and aluminum rivets can be used to reduce the overall weight of the structure. The low carbon steel is standardized in composition particularly for boiler applications. Rivets with counter sunk head as in Figure 3.2(b) and oval counter sunk rivets shown inGet Price

  • Model Engineer

    Jan 04, 2012 · JasonB, on the Mamod(SE-2 I think mine is) to fill remove safty valve and put in the little plastic funnel, remove the plug in the end of the boiler, fill with water untill it comes out of the hole in the end of the boiler, replace the plug and valve. you could pressurise via the end plug, the whistle, or the safty valve.Get Price

  • Mamod SW1 Conversion - Roly Williams

    Finally, the name board was cut out and araldited in place. For a livery, I decided on dark green for the bodywork, chassis and wheels, lined with yellow. The boiler, firebox and smokebox are black. I painted the flat bed brown to look like wood and, as an added touch, I gave the chimney top a copper coloured rim.Get Price

  • THROWBACK MODELLER

    copper cut to size, was put through a set of borrowed boiler rolls using a wooden master [kitchen rolling pin] to gauge progress. A few copper rivet positions were used to hold the tube shape and 1/8 of an inch copper blanks were pressed in to the ends. WithGet Price

  • Locobox Sophie - Garden Railway Club

    To get at the radio Rx and batteries, I had to remove the saddle and side tanks, which are in one piece. Much staring at it revealed that these were held at the back by two captive (thankfully) bolts and at the front by a plate which goes round the boiler. With the tanks off, I had a real game getting the battery pack and receiver out.Get Price

  • Mamod - Wikipedia

    The exhaust was a simple open port in the engine frame as per the MEC1 and the engine carried two makers' marks — a Mamod and a Meccano type scalloped edge decal. The baseplate was silver painted and the boiler was a standard Mamod drawn type tube as used on the SP2, SP4 and SR1a. The SP3 could drive the whole series of workshop tools.Get Price

  • Boiler Items - Model Enthusiasts

    Mar 19, 2007 · I've been thinking a bit more about this. I think I'll leave it as rivets for the site glass but instead of puting rivets back in to hold the SP4 boiler back into the firbox I will put brass bolts inside the boiler with the threads poking outside the boiler and solder the head to the inside of the boiler so the head of the bolt and the solder will form a steam tight seal and the nuts will just Get Price

  • Repairing a loose whistle bush on a Mamod mobile

    Repairing a loose whistle bush on a Mamod mobile Anybody who has restored a few Mamod mobile engines is likely to have come across this problem. The bush holding the whistle is situated on the top of the boiler, directly above the burner and is enclosed by the firebox cowling. The solder often gives way and the thread is seized due to corrosion.Get Price

  • Mamod steam locomotive - Pearltrees

    The copper saddle on the chimney is nicely flared out at the base and is riveteed to the smokebox with four tiny copper rivets. Theres a proper double crosshead slide which all operates beautuifully. work on even a low pressure boiler like a Mamod, you have to know precisely what you are doing, and exactly why. The Mamod boiler, if in sound Get Price

  • Soldering/brazing a boiler. - Model Engineer

    May 11, 2014 · Mamod offer two steam pressure valves : for older and newer models. They both have a thread on them. I do not think they would screw into the top of my boiler so would it be okay to solder them in ? I read the above link and he used wet rags around the ends of the boiler to prevent desoldering of the ends while he added the fittings.Get Price

  • Two ways to get copper rivets out of a Mamod boiler - The

    One: Aluminium Pop Rivet 3/32 inch. Four of these are used to hold the Fire Box to the Engine Cowl. Two: Aluminium Pop Rivet 1/8 inch. Two are used to hold the Engine Frame (crankshaft etc.) to the Engine Cowl. Two are used to secure the Smoke Box (chimney assembly) to the Boiler. Three: Copper Closed End Rivet 3.2 mm.Get Price

  • WHICH RIVETS - Mamod Steam Engine Guru

    Nov 24, 2013 · Put one nut on up to the boiler closing plate and lock two on the end of the screw. Hold the locked nuts and tighten the nut against the boiler; remove locked nuts. Apply a splash of solder to fully seal and melt solder off screw head inside boiler. Cut studs to length. I use 1/8 BSW screws and nuts to secure the fire box.Get Price

  • Steaming up a Mamod Minor 2 steam engine for the first

    It seems to work OK but I overfilled the boiler with water, and then the flywheel came loose. x. My supplier for Mamod copper rivets for shipping to US: x. MAMOD MINOR 2 / FLAT BASE STEAM ENGINE QOKT4259 5:20. A very nice Mamod Minor 2 which a purchased on ebay just for the burner. Which unfortunately turned out to be full of holes! The Get Price

  • Boiler Pressure Guide - EDF

    Oct 02, 2020 · Normal boiler pressure should be between about 1-2 bars [3]. The ideal boiler pressure is often marked as a range in green on the gauge itself. With red indicating the low and high boiler pressure zones. Bear in mind that your boiler may continue to work if the pressure is in these red zones.Get Price

  • Roundhouse Bertie - Garden Railway Club - Google Search

    Roundhouse Bertie. Here is an introduction to the Roundhouse Basic Series "Bertie" from Roundhouse Engineering. This is a simple, slip eccentric loco, but has an excellent, internally gas fired boiler and powerful cylinders. It is a steady runner from what I have seen so far, and is relatively simple to modify.Get Price

  • 16mm Tram - Kitbuilding & Scratchbuilding - RMweb

    Jan 08, 2011 · After a long time of thinking (about two months) i finaly decided to do it. So and ordered the following parts to start my self off: x1 Mamod SR1A boiler. x1 3mm copper rivets. x1 1/4" thread safty valve. x1 1/4" thread foot pump adaptor. x2 1/8" diameter x 12" long copper pipe. x6 .008x4x10" tin sheet.Get Price

  • Blog of the Building of a Stanley Style - Roly Williams

    The boiler is in the way of replacing the old steering column as it was. As far as I can see, I have two alternatives: 1 - the simple one of not bothering, or 2 - to make up some sort of linkage to couple the steering wheel to the front wheels.Get Price

  • UNDERSTANDING HOT WATER SYSTEMS IN THE HOME …

    There are two ways of providing hot water to the home: A) one using a hot water cylinder to give a store of hot water. B) using a combination boiler or multipoint water heater to give instant hot water. Before deciding which system is right for you, your plumber needs to know how much water will be used at any one time and for how long. In summaryGet Price

  • MAMOD (and WILESCO) BOILER FILLER & SUCKER TE1A and ALL

    Established 2004 BOILER WATER FILLER & SUCKER FOR MAMOD AND WILESCO ENGINES "You are fed up with spending too long dribbling water into your boiler and then spilling it everywhere." This is so simple. Use this bad boy to suck up a gulp of hot water and just squirt it into the boiler. It takes seconds! And then suck out excess water after the steam-up.Get Price

  • Old Mamod Engine problem - G Scale Central

    Jan 05, 2011 · I have an old complete set Mamod steam railway with the little engine, a boxcar and a guard van, which I get out and run periodically while saving up to move into 45mm live steam with the Accucraft Peveril. I have noticed a potential problem with my little Mamod though. I think it has a crack in the boiler water viewing glass, in fact I'm quite Get Price

  • The Regner Vincent - Garden Railway Club - Google Search

    The cut out for the boiler was there, and two small spectacle holes, but the rest was still just sheet brass. I marked out the width of the cab and cut the sheet into three, using a multi-purpose chop (or mitre) saw. These are pretty violent and it is essential to wear eye protection as you get showered with hot metal.Get Price

  • A Smaller Steam Boat - RC Groups

    Oct 18, 2016 · Two for the sight glass. One for feed water. Two for pressure relief valves, a primary and secondary set 5psi higher. One for steam supply. One for the pressure gauge, and one spare for filling up the boiler and or a hand pump. Eight total. Next set of photos is the riveting of the end plates. I used 1/8 inch copper rivets from McMaster Carr.Get Price

Discount
7X24 Online