Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Study on the boiler drum water level based on Fuzzy

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Study on the boiler drum water level based on Fuzzy
  • Supply Capacity : 10 units/month :Study on the boiler drum water level based on Fuzzy
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • The Design for Feed Water System of Boiler Based on Fuzzy

    May 01, 2010 · The self-adaptable fuzzy-PID control method is applied in automatic control of boiler drum water level, under the situation of interaction and no interaction, the simulation research is done to PIDGet Price

  • Study on Fuzzy Self-Adaptive PID Control - CyberLeninka

    Conventional PID Control System can not reach a satisfaction result in nonlinearity and time different from Biomass Boiler Drum Water Control System. In this study, a kind of fuzzy self-adaptive PID controller is described and this controller is used in biomass boiler's drum water level control system.Get Price

  • The research on boiler drum water level control system

    May 25, 2012 · Abstract: The boiler control is the thermal power plant most basic industrial control. The cascade-three parameters water level control system includes steam drum water level, steam flow and water supply, adjust water supply for the opening, Fuzzy adaptive control by seeking the three parameters of PID controller and the relationship between e and ec, make the …Get Price

  • Optimization control strategy of boiler water level based

    May 30, 2016 · Due to boiler water level nonlinear, delayed and non-minimum phase characteristics, meanwhile there also has no precise mathematical model and with the problem about traditional PID control parameters are fixed which lead to an undesired control effect. Therefore, this article presents an optimal control scheme based on fuzzy PID algorithm. The …Get Price

  • Influence of Boiler Load Swing Rates on Response of Drum

    Apr 22, 2013 · The nonlinear boiler model employed in study investigations was validated by comparing simulated results against literature data. Experimental field data was recorded for variations in firing, steam, and feedwater flow rates in addition to drum pressure and water level were obtained from a Saudi Aramco power plant.Get Price

  • Level Control In Boiler Using Matlab

    Water Level Control System of Boiler Drum Based on GPC April 10th, 2019 - The paper discusses a TS fuzzy model identification method for an industrial drum type boiler plant using the fuzzy clustering approach The fuzzy model is constructed from a set of input output data that covers a wide operating range of the plant Then this paper studies Get Price

  • Research on Water Level Optimal Control of Boiler Drum

    May 29, 2011 · Boiler drum system is an important component of a thermal power plant or industrial production, and the water level is a critical parameter of boiler drum control system. Because of non-linear, strong coupling and large disturbance, it is difficult to reach a suitable working state of drum system by using traditional control methods.Get Price

  • Research on Boiler Drum Water Level System Based on Fuzzy

    Abstract: Boiler is an important thermal energy supply equipment of the industrial processes,the degree of automation determines the quality of superheated steam,the safety of the production process,the labor intensity and personal safety of the operators,and the water level of the drum is an important control parameter.The traditional drum water level is controlled by PID,but …Get Price

  • Feedwater Level Control of Boiler Steam Drum using IMC and

    Jun 22, 2015 · The motion equation of regulation of drum water level under the effect of water supply flow can be expressed as: Drum is extracted from Juhua Wang and QingjinMeng, [2] 2 + = + (4) which involves the state space dynamics of steam Drum. 1 2 2. 1 . and LQR is designed to make the boiler drum water level control. Controller design based on Immune Get Price

  • Boiler Control Design Using Fuzzy Logic - Afribary

    This thesis presents the application of a fuzzy logic based controller for boiler turbine plant to control the drum pressure, power output and water level. Fuzzy control system have been successfully applied to a wide variety of practical problems. It has been shown that these controllers may perform better than conventional controllers Get Price

  • WATER LEVEL MONITORING AND CONTROL USING FUZZY …

    fuzzy logic for water level control in boiler drum and combustion quality control. The control system can efficiently reduce the uncertain disturbances from real environment. Recently, Shome and Ashok [9] described an intelligent controller using fuzzy logic to meet the nonlinearity of the system for accurateGet Price

  • Fuzzy Logic Execution in Boiler Control - IJSRD

    problems of boiler examples of water level in boiler drum and combustion quality control s presented. Fuzzy control rules were extracted from operator knowledge based on the relative relevance ruling criteria for existing boiler room. Proposed fuzzy control design a simulation system of fuzzyGet Price

  • Fuzzy Adapting PID Based Boiler Drum Water Level Controller

    thermal power plant controls. Boiler water level control system includes steam drum water level, steam flow and water supply. The control objective is to control the water level of boiler drum. Fuzzy Adaptive PID controller is designed for controlling the …Get Price

  • Level Control In Boiler Using Matlab

    Level Control Using Fuzzy. WATER LEVEL CONTROLLER BY FUZZY LOGIC. Vol 4 Special Issue 6 May 2015 Monitoring And. Fuzzy Logic Approach For Boiler Temperature Amp Water Level. Optimizing Drum Boiler Water Level Control Performance A. Simulation Of Domestic Boiler Control IJSSST. PLC Amp SCADA Based Effective Boiler Automation System For. MATLAB DRUMGet Price

  • john thompson boilers – Industrial Autoclave & Boiler Sale

    John Thompson Water Tube Boilers Ltd. Natural and forced circulation water boilers. Boilers of all types for land, marine and for utilizing waste heat. May 23, 2016 · John Thompson (JT) is a division of ACTOM (Pty) Ltd with its principal focus on being the best boiler and environmental solutions company serving the powerGet Price

  • Speed control of boiler feed water pump turbine based on

    Jan 17, 2017 · One of the most important controlled parameters of thermal power units is the boiler drum water level. Disturbances of feed water flow rate could cause instability of the drum water level. This study proposes the Gray correlation compensation (GCC) control technology for the Boiler feed water pump turbine (BFPT) to solve this problem. Simulation results indicate …Get Price

  • price list boiler jhon thompson – Industrial Fire Tube Boiler

    Apr 22, 2020 · Ask Price View More; Used 1987 John Thompson Steam Boiler John Thompson SD-15 1 . Steam Boiler, Brand: John Thompson, Model: SD-15, Capacity: 1,500kw. Unit is a gas fired water tube unattended steam boiler. Design Pressure: 1200 KPA. Ask Price View More; Package Boilers The JOHN THOMPSON P – YumpuGet Price

  • 167 Analysis of Different Controllers used for Boiler Drum

    Drum Level Control Systems are used extensively throughout the process industries. It is used to control the level of boiling water contained in boiler drums and provide a constant supply of steam. There are three different types of boiler drum level control: A. single element boiler drum level control B. two element boiler drum level controlGet Price

  • Optimization and Simulation of Boiler Water Level Control

    Optimization and Simulation of Boiler Water Level Control Based on the Fuzzy Neural Network Zhimin Yu 1*, Long Cheng2, Zhenyong Hao 3 and Renzhong Wang 4 1Tianjin maritime college. 300350 .China 2Tianjin Maritime Safety Administration .300351.China 3China Oilfield Services Limited 300351.China 4School of ocean Yan tai University.264000.China *Corresponding authorGet Price

  • Level Control In Boiler Using Matlab

    Boiler Using Matlab Howtogetitincanada Com. Fuzzy Logic Based Boiler Drum Level Control With GUI. Fuzzy Adapting PID Based Boiler Drum Water Level Level Control Using Labview Ijcaonline Org. Vol 5 Issue 6 July 2016 A Case Study Of Three Drum. A New Method For Controlling Boiler Of Thermal Power Plant June 21st, 2018 - Fuzzy Adapting PID Get Price

  • Drum Water Level Control Based on Improved ADRC - MDPI

    Jun 28, 2019 · Advanced control strategies are more and more frequently used in water level control of the boiler drum, and have made great achievements. Jin [] proposed a self-adaptive fuzzy-PID control method by combining PID theory with fuzzy control.Wang [] introduced the Linear Quadratic Regulator (LQR) algorithm into conventional water level control strategy, and …Get Price

  • (PDF) Application of Fuzzy Logic in Boiler Control

    Application of fuzzy logic for solving the control problems of boiler room shown on the examples of water level control in boiler drum and combustion quality control is presented. Fuzzy control rules were extracted from operator knowledge based onGet Price

  • 167 Analysis of Different Controllers used for Boiler Drum

    Drum Level Control Systems are used extensively throughout the process industries. It is used to control the level of boiling water contained in boiler drums and provide a constant supply of steam. There are three different types of boiler drum level control: A. single element boiler drum level control B. two element boiler drum level controlGet Price

  • Development of Fuzzy Controller for Water Level in Stream

    Results: The fuzzy control was developed, which consists of two input variables, the degree of temperature and pressure in boiler tank measured by sensor. For fuzzy system of water level control, the algorithm is basically implemented in form of the MATLAB code. In the experiment, we assumed that the water level would not effect to the Get Price

  • Study on the boiler drum water level based on Fuzzy

    In the boiler drum water level fuzzy control system, fuzzy control method is the most dominant control method, which based on fuzzy logic theory, fuzzy set theory and fuzzy language variables. The fuzzy PID boiler water level control system is investigated and analyzed in terms of model and characteristics.Get Price

  • A_REVIEW_ON_MODERN_APPROACH_TO_THE_FUZZY.pdf

    A REVIEW ON MODERN APPROACH TO THE FUZZY LOGIC BASED BOILER DRUM LEVEL CONTROLLER R.Muthukrishnan, Dr.,S.Prakash, Dept of EEE, BIHER, BIST, Bharath University, selaiyur,Chennai-73. Abstract - Based on the analysis of dynamic characteristics of the drum water level, a control strategy of the drum water level in a CFB using fuzzy logic boiler is …Get Price

  • Design of Fuzzy PID Controller for Water Level of Boiler

    A control system for water level of boiler steam drum based on DSP microprocessor is designed in this paper. The technique of fuzzy control was applied to controlling the water level of the steam drum, the operational principle and application of the fuzzy-PID arithmetic are described. The water level controller with good control effect is developed.Get Price

  • IJETT - Improved Inverse Response of Boiler Drum Level

    [11] Liang Chen1, Cuizhu Wang, "The research on boiler drum water level control system based on self-adaptive fuzzy-PID," IEEE, Chinese Control and Decision Conference, 2010, 1582-1584. Keywords Inverse Response, IMC Controller, Fuzzy Control, Fuzzy Adaptive PID.Get Price

  • Design of Fuzzy PID Controller for Water Level of Boiler

    Design of Fuzzy PID Controller for Water Level of Boiler Steam Drum Based on DSP. Xin, Yuan Fang. Abstract. Publication: Applied Mechanics and Materials. Pub Date: October 2011. DOIGet Price

  • Real-time temperature field reconstruction of boiler drum

    Mar 01, 2017 · Boiler drum is a thick wall cylinder with the outer wall covered by a thick layer of insulation. In a drum, the lower part (under the water level) is boiler water while the upper (above the water level) is saturated steam, as shown in Fig. 1.The following assumptions are made: 1) The wall's axial heat conduction is ignored; 2) The outer wall of the drum is insulated; 3) …Get Price