Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Munchkin Boiler- I am getting an F14 error code and the

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Munchkin Boiler- I am getting an F14 error code and the
  • Supply Capacity : 10 units/month :Munchkin Boiler- I am getting an F14 error code and the
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • F13 error on Munchkin T50 - Heating Help: The Wall

    The technician inspected the boiler, disassembled the blower assembly, and blew a ton of sawdust out of it. (This is presumably the result of having woodworking tools in the same basement as the boiler. I will try to seal the boiler cabinet somewhat and---to some extent---wall off the room in which the boiler lives.Get Price

  • F09 Error code on Muchkin 140M — Heating Help: The Wall

    This fall upon initial fire up I was getting a F09 code maybe once a week and then it quit. Now that spring has come around and my boiler fires less it throws the F09 much more often. It seems if you can get it and keep it running its ok, its only when it sits for a while not running then throws the code more often?Get Price

  • Ravenheat error code 28 | DIYnot Forums

    Sep 03, 2019 · 4,595. Location: London. Country: Well Andrew we are not permitted to give advice on gas or combustion aspects to DIYers. You should not have even opened the boiler casing as its a room sealed unit. I don't see why you were looking at the flue sensor. F28 seems to relate to the water pressure switch! Usually just needs water pressure topping up Get Price

  • navien ch240 hot water is working but not heating the

    Dec 19, 2017 · Boilers - Home Heating Steam and Hot Water Systems - navien ch240 hot water is working but not heating the house - The problem started this morning / last night. I'm still getting hot water on the DHW side but not getting any hot air from my air handler. The pipes that go to the air handler are cold to touch, I suspectGet Price

  • Munchkin Boiler Problems - HVAC-Talk

    Oct 20, 2014 · Munchkin Boiler Problems. Hello, My home is heated (radiant floor) via Munchkin mc120 boiler. We recently got the f13 code for blower motor. Installed in 2008, first blower replace. Also replaced control board recently. I do most work on my house, and this looks like a very easy replacement, but it looks like there's a sequence to it- can Get Price

  • Gas fired hot water boiler not burning (Pilot light on

    Oct 23, 2012 · Boilers - Home Heating Steam and Hot Water Systems - Gas fired hot water boiler not burning (Pilot light on) - Hello, I bought the house earlier this year, and i was pretty sure the heat was working when the prev owner flick the switch to On. I had a contractor which was helping me doing some renvoation, and i know heGet Price

  • M80 Munchkin boiler leaking :O - DoItYourself.com

    Dec 18, 2017 · Boilers - Home Heating Steam and Hot Water Systems - M80 Munchkin boiler leaking :O - Greetings all, Well, my 12 (?) year Munchkin M80 had a new blower installed less than a year ago (thanks for your help on that one!). And boiler was working fine - until yesterday. Wouldn't heat past 90 degrees and showed ye olde F-09Get Price

  • munchkin boiler - Yahoo Search Results

    Munchkin Boilers - 3 Boiler Bids You Should See. remodelrepairreplace.com has been visited by 10K+ users in the past month . Compare Munchkin Boiler Prices. Enter Zip & Get 3 Bids in Seconds. Your Boiler Needs to Work Every Time. Trusted Companies with Track Records of …Get Price

  • How to Reset a Munchkin Boiler | eHow

    Take the appropriate action to fix the problem, as indicated in the boiler manual. The boiler is ready to be reset once you have completed any repair work.Get Price

  • Problem Pinnacle, need some help — Heating Help: The Wall

    The boiler was displaying a F14 fault code which means combustion fan speed is too high(or wiring, or control board) . I spoke with Peerless tech support at that time who told me to test the fan by disconnecting the control wiring and observing the fan going to high speed.Get Price

  • Munchkin T80 E14 followed by F14 fan speed error codes

    Mar 23, 2011 · Munchkin Boiler- I am getting an F14 error code and the boiler shuts down. It's a model # XXXXX - R2. Manufactured in 2007. The aluminum parts are shiny. The fan doesn't make any noise to indicate the blades are bad. How do I determine if it's the blower or the control board? The boiler will only run a couple of hours before it trips out again.Get Price

  • Munchkin Control Board Fault Codes - JupiterHeating.com

    This boiler must be installed by qualified and licensed personnel. The installer should be guided by the instructions furnished with the boiler, and with local codes and utility company requirements. In the absence of local codes, preference should be given to the National Fuel Gas Code, ANSI Z223.1 – latest edition. INSTALLATIONS MUST COMPLY Get Price

  • Parts for the Munchkin 399M Boiler, Revision 1

    Directory: Catalog > Boilers & Water Heaters > Heat Transfer Products (HTP) > Parts. Parts for the Munchkin 399M Boiler, Revision 1. Match the Item # on the chart with the same Item # indicated on one of the two line art diagrams below the chart. Items not currently for sale on our site do not have yellow links and are marked with an asterisk.Get Price

  • Munchkin Boiler F13 Error Code - 07/2021 - Couponxoo.com

    HTP Munchkin Boilers - Furnace Compare. Discover The Best Deals .furnacecompare.com · What does a Munchin fault code F-02 mean? Answer: According to page 63 of the Munchkin Gas Fired Boiler manual: Fault Code F03 description: "Interrupted or Shorted Return (Inlet) Thermister." To fix/remedy the problem: Check the electrical connection to the thermister on the outlet …Get Price

  • Munchkin Gas-Fired Boiler - htproducts.com

    This boiler must be installed by qualified and licensed personnel. The installer should be guided by the instructions furnished with the boiler, and with local codes and utility company requirements. In the absence of local codes, preference should be given to the National Fuel Gas Code, ANSI Z223.1 – latest edition. INSTALLATIONS MUST COMPLY Get Price

  • Munchkin 140m F14: blower and/or circulation problem

    Dec 16, 2012 · Boiler has begun throwing intermittent F14 codes, like once every day or two. F14 is a fan speed error, "blower too fast, more than 130% of expected rate for more than 60 seconds." I read F14 usually the blower, sometimes the control board. Both are original on this unit. I am trying to troubleshoot before I spring for a $400 part.Get Price

  • MUNCHKIN T80M IS A LEMON - HVAC-Talk

    Dec 04, 2013 · Dear Mr. Daniels: I am again reporting that the number of repairs within the short time I have lived here at this home --which was a brand new home in which your new Munchkin T80M was installed in 2005--has been excessive and a certain indication that this boiler is a LEMON. Our plumber just replaced the blower/fan unit yet again. The history of replacing and …Get Price

  • Installing, Operating & Maintaining MUNCHKIN™ HIGH

    1. The Munchkin Boiler is certified for clos-et installations with zero clearance to combustible construction. In addition, it is design certified for use on combustible floors. 2. Refer to Figure 1.1 and Figure 1.2 for the recommended clearance to allow for rea-sonable access to the boiler. Local codes or special conditions may require greater Get Price

  • Boiler Bosch Condens 8700i - error code H11/1021 · Issue

    Dec 20, 2021 · ems-esp:$ read 8 c2 000+00:15:17.437 N 0: [emsesp] Boiler(0x08) -> Me(0x0B), UBAErrorMessage3(0xC2), data: 08 C3 00 10 11 48 31 31 03 FD 95 0C 0F 18 32 00 00 00 00 00 08 C3 00 10 11 48 31 000+00:15:17.653 N 1: [emsesp] Boiler(0x08) -> Me(0x0B), UBAErrorMessage3(0xC2), data: 31 03 FD 95 0C 0D 13 12 95 0C 10 14 21 08 C3 00 10 11 48 …Get Price

  • Munckin 140m F14 error: blower and/or circulators

    Sep 07, 2021 · Problem 2: High Combustion Fan Speed (Error Code- F14) Low combustion fan speed hampers the boiler performance. Similarly, high combustion fan speed can damage the boiler components.Get Price

  • Munchkin Boiler- I am getting an F14 error code and the

    in THE MAIN WALL. 2200 sq ft residence, converted gravity with cast iron radiators plus second RFH zone, Munchkin 140M mod/con is about 7 years old with 925 control panel and Vision (outdoor reset) control. Boiler has begun throwing intermittent F14 codes, like once every day or two. F14 is a fan speed error, "blower too fast, more than 130% of expected rate for more than …Get Price

  • Munchkin Boiler Problems [9 Easy Solutions]

    F14: Combustion Fan Speed High – The boiler will lock out if the fan speed is more than 130%of expected rate for more than 60 seconds. Check the combustion air fan wiring. Replace the combustion blower motor. Replace the control board. F18: Gas Valve Error: Make sure the connector is correctly connected to the gas valve.Get Price

  • Which Boiler Should we Purchase to replace Munchkin

    Any recommendation on a boiler that we should look at or ones to stay away from? I am totally new at radiant heat and would love to get a few opinions on good quality options and ones to avoid. Thanks a ton! JohnGet Price

  • Munchkin Boiler not firing up - no error codes

    Sep 22, 2016 · Since you aren't getting any trouble codes you are either losing 120vac power or you are losing the thermostat connection to the boiler. I don't know if there is an indicator that lets you know you have 120v present.Get Price

  • Munchkin Gas-fired Boiler Operating instructions | Manualzz

    5. The Munchkin Boiler shall be installed so the gas ignition system components are protected from water (dripping, spraying, rain, etc.) during appliance operation and service (circulator replacement, condensate trap, control replacement, etc.) D. OPERATING INSTRUCTIONS 1. STOP! Read the safety information in Part 6.Get Price

  • Ask Vaillant | Domestic Boilers | Vaillant

    Air Lock Within The Boiler Or The System. Blockage Within The Boiler Or The System. System Design Issue. Insufficient System Bypass. NTC Thermistor Out Of Calibration (Should Read 12Kohms @ 20C) Harness Fault Between The Overheat Thermostat And The Main PCB Fault Code F6 Thermistor FaultGet Price

  • Parts for the Munchkin T80M Boiler, Revision 1

    Directory: Catalog > Boilers & Water Heaters > Heat Transfer Products (HTP) > Parts. Parts for the Munchkin T80M Boiler, Revision 1. Match the Item # on the chart with the same Item # indicated on one of the two line art diagrams below the chart. Items not currently for sale on our site do not have yellow links and are marked with an asterisk.Get Price

  • Munchkin Boiler Error Code Pro, 01-2022

    The Munchkin 80M boiler is a gas-fired boiler that was designed for residential homes. This boiler is rated at 92% efficiency and an Input Btu's of 27,000 to 80,000 Btu's. The Department of Energy Rated Heating Capacity is 25,000 Btu's to 74,000 Btu's.Get Price

  • Munchkin Gas-Fired Hot Water Boiler Specifications - manualzz

    View online(81 pages) or download PDF(8.09 MB) HTP Gas-Fired Hot Water Boiler Specifications • Gas-Fired Hot Water Boiler water heaters & boilers pdf …Get Price

  • I have an M80 Munchkin boiler and and getting an F02 error

    Oct 17, 2017 · I have a 2003 munchkin 199,000 boiler. I get a F-14 fault code, then I press S4, blower comes on fast, then slows down, then I get a E-14 code, then I unplug the top plug on the blower, press S4, get … read moreGet Price